Sign In | Join Free | My himfr.com
himfr.com

Qingdao AIP Intelligent Instrument Co., Ltd

Qingdao AIP Intelligent Instrument Co., Ltd Customer - Oriented, Striver - First

Active Member

8 Years

Home > Safety Testing System >

Washing Machine Safety Testing System High Precision Low Power Consumption

Qingdao AIP Intelligent Instrument Co., Ltd
Contact Now
    Buy cheap Washing Machine Safety Testing System High Precision Low Power Consumption from wholesalers
     
    Buy cheap Washing Machine Safety Testing System High Precision Low Power Consumption from wholesalers
    • Buy cheap Washing Machine Safety Testing System High Precision Low Power Consumption from wholesalers
    • Buy cheap Washing Machine Safety Testing System High Precision Low Power Consumption from wholesalers
    • Buy cheap Washing Machine Safety Testing System High Precision Low Power Consumption from wholesalers

    Washing Machine Safety Testing System High Precision Low Power Consumption

    Ask Lasest Price
    Brand Name : AIP
    Model Number : AIP89XX
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 50 sets per month
    Delivery Time : 45 work days
    • Product Details
    • Company Profile

    Washing Machine Safety Testing System High Precision Low Power Consumption

    Safety Testing System / Electrical Safety System for Washing Machine


    1. Features:

    • Test fast: the control core of testing system adopts ARM high-speed processor.
    • High precision: the precision of safety testing system is up to 1.5%.
    • AC Hipot voltage support ramp up and down setting, upper and lower limit alarm setting.
    • Digital closed-loop feedback control mode, automatic voltage adjustment mode, self-checking of output voltage and current without influence of the external power supply, all these features ensure the accuracy of rest results.
    • To satisfy all the requirements of different country or industry, the ground resistance testing can be measured by voltage or resistance.

    2. Technical parameters:

    AC Hipot

    Output voltage setting range/precision

    AC 200~5000V ±(3%*setting value + 5 digit)

    Breakdown current measuring range/precision

    0.10~99.99mA ±(3%*displayed value + 5 digit)

    Presetting breakdown current alarm range/precision

    Up limit: 0.10~99.99mA;

    Lower limit: 0.00~5.00mA

    Testing time range/resolution

    1~300S 1s/step

    Insulation resistance

    Output voltage setting range/precision

    DC 500/1000V ±(3%*displayed value + 5 digit)

    Insulation resistance measuring range/precision

    1~2000MΩ Within 100MΩ: ±(5%*displayed value + 3 digit);

    Above 100MΩ: ±(8%*displayed value + 8 digit);

    Presetting insulation resistance alarm range/precision

    Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ

    Testing time range/resolution

    1-300s 1s/step

    Grounding

    Ground current output range/precision

    AC 5.0~30.0A ±(3%*setting value + 5 digit)

    Ground resistance measuring range/precision

    10.0~600mΩ ±(3%*displayed value + 5 digit)

    Presetting ground resistance alarm range

    Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ

    Lower limit: 0.0 ~100mΩ

    Testing time/resolution

    1~60s 1s/step

    Leakage current

    Output voltage

    1.06 times of nominal voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Leakage current measuring range/precision

    0.05~20.00mA ±(3%*displayed value +0.02mA)

    Presetting leakage current alarm range

    Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA

    Testing time range/resolution

    1~300s 1s/step

    Power

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Output current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Power measuring range/precision

    30~6000W ±(0.5%*displayed value + 5 digit)

    Presetting power alarm range

    Up limit: 30~6000W; Lower limit: 0~6000W

    Low voltage starts

    Output voltage

    O.85 times of input voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Starting current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Presetting current alarm range

    Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A

    Testing time/resolution

    1~300s 1s/step