Sign In | Join Free | My himfr.com
himfr.com

Qingdao AIP Intelligent Instrument Co., Ltd

Qingdao AIP Intelligent Instrument Co., Ltd Customer - Oriented, Striver - First

Active Member

8 Years

Home > Safety Testing System >

Grey Color Electrical Safety Test Equipment For Electric Water Heater

Qingdao AIP Intelligent Instrument Co., Ltd
Contact Now
    Buy cheap Grey Color Electrical Safety Test Equipment For Electric Water Heater from wholesalers
     
    Buy cheap Grey Color Electrical Safety Test Equipment For Electric Water Heater from wholesalers
    • Buy cheap Grey Color Electrical Safety Test Equipment For Electric Water Heater from wholesalers
    • Buy cheap Grey Color Electrical Safety Test Equipment For Electric Water Heater from wholesalers
    • Buy cheap Grey Color Electrical Safety Test Equipment For Electric Water Heater from wholesalers

    Grey Color Electrical Safety Test Equipment For Electric Water Heater

    Ask Lasest Price
    Brand Name : AIP
    Model Number : AIP89XX
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 50 sets per month
    Delivery Time : 45 work days
    • Product Details
    • Company Profile

    Grey Color Electrical Safety Test Equipment For Electric Water Heater

    Safety Testing System / Electrical Safety Testing System for Electric Water Heater


    1. Features: six test items can be finished in sequence at one time, AC Hipot, insulation resistance, grounding, low voltage start and power, the test order can be set as per your requirement. Reduce labor work, save testing space and improve production efficiency.


    2. Tested object: home appliances / electric water heater


    3. Technical parameters:

    AC Hipot

    Output voltage setting range/precision

    AC 200~5000V ±(3%*setting value + 5 digit)

    Breakdown current measuring range/precision

    0.10~99.99mA ±(3%*displayed value + 5 digit)

    Presetting breakdown current alarm range/precision

    Up limit: 0.10~99.99mA;

    Lower limit: 0.00~5.00mA

    Testing time range/resolution

    1~300S 1s/step

    Insulation resistance

    Output voltage setting range/precision

    DC 500/1000V ±(3%*displayed value + 5 digit)

    Insulation resistance measuring range/precision

    1~2000MΩ Within 100MΩ:±(5%*displayed value + 3 digit);

    Above 100MΩ:±(8%*displayed value + 8 digit);

    Presetting insulation resistance alarm range/precision

    Up limit: 0~2000MΩ; Lower limit: 1~2000MΩ

    Testing time range/resolution

    1-300s 1s/step

    Grounding

    Ground current output range/precision

    AC 5.0~30.0A ±(3%*setting value + 5 digit)

    Ground resistance measuring range/precision

    10.0~600mΩ±(3%*displayed value + 5 digit)

    Presetting ground resistance alarm range

    Up limit: 5~10A 10.0~600mΩ; 11~25A 10.0~300mΩ; 26~30A 10.0~200mΩ

    Lower limit: 0.0 ~100mΩ

    Testing time/resolution

    1~60s 1s/step

    Leakage current

    Output voltage

    1.06 times of nominal voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Leakage current measuring range/precision

    0.05~20.00mA ±(3%*displayed value +0.02mA)

    Presetting leakage current alarm range

    Up limit: 0.05~20.00mA; Lower limit: 0.01~5.00mA

    Testing time range/resolution

    1~300s 1s/step

    power

    Output voltage

    Equals input voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Output current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Power measuring range/precision

    30~6000W ±(0.5%*displayed value + 5 digit)

    Presetting power alarm range

    Up limit: 30~6000W; Lower limit: 0~6000W

    Testing time/resolution

    1~300s 1s/step

    Low voltage starts

    Output voltage

    O.85 times of input voltage

    Output voltage measuring range/precision

    AC 50~280V ±(0.5%*displayed value + 2 digit)

    Starting current measuring range/precision

    AC 0.20~30.00A ±(0.5%*displayed value + 2 digit)

    Presetting current alarm range

    Up limit: 0.20~30.00A; Lower limit: 0.00~25.00A

    Testing time/resolution

    1~300s 1s/step


    4. Main characteristics:

    • Meet the common electrical safety testing standards and requirements of CCC, ICE, EN, VDE, BS, GS, UL.
    • Optionally equipped with industrial computer, and to accomplish automatic control and data recording by using a barcode scanner device, and to build a platform of managing production data, and to communicate with the production management system.
    • Optionally equipped with the inverter to achieve automatic test, and the output voltage will be changed automatically. It has no effect on output results.
    • Storage space of test items and results is unlimited, maximum 8 test procedures for each testing group, each test group can be established with a type name. Type querying is available.
    • Test results can be exported via USB flash.

    5. Image of tested objects for reference

    Quality Grey Color Electrical Safety Test Equipment For Electric Water Heater for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Qingdao AIP Intelligent Instrument Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)