Sign In | Join Free | My himfr.com
himfr.com

Qingdao AIP Intelligent Instrument Co., Ltd

Qingdao AIP Intelligent Instrument Co., Ltd Customer - Oriented, Striver - First

Active Member

8 Years

Home > Safety Testing System >

Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor

Qingdao AIP Intelligent Instrument Co., Ltd
Contact Now
    Buy cheap Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor from wholesalers
     
    Buy cheap Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor from wholesalers
    • Buy cheap Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor from wholesalers
    • Buy cheap Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor from wholesalers

    Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor

    Ask Lasest Price
    Brand Name : AIP
    Model Number : AIP965X series
    Price : Negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 50 sets per month
    Delivery Time : 20 working days
    • Product Details
    • Company Profile

    Electrical Safety Testing System AC Hipot Test With 19" LCD Monitor

    Electrical Safety Testing System/Machine/Safety Testing Solution


    1. Safety testing system introduction

    This electrical safety testing system supports to test leakage current, AC Hipot, insulation resistance, grounding resistance, no load power and low-voltage start up. Up to 100 sets of testing conditions can be memorized. With 8 testing steps, each set’s specification model can be set individually for quick search. Hi-pot voltage is featured with ramp up/down setting, max./min. alarm. Digital closed-loop feedback control mode, automatic voltage adjustment mode, output voltage/current automatic correction avoid the influence of grid fluctuation, all of these ensure the test precision. Meet requirements in CCC, IEC, EN, VDE, BS, GS, UL and other general electrical safety specifications.


    2. Product accessory

    Power cord×1, foot switch×1, 30A testing pliers×2, testing box×1, power input line×1, protective tube×1, user manual×1, alarm light×1


    3. Technical parameters

    Leakage current
    Output voltage1.06 times rated voltage, built-in variable frequency inverter
    Leakage type settingDynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely.
    Output voltage setting range/precisionAC 50~280V ±(0.5%×display value+2 words)
    Leakage current setting range/precision0.05~20.00mA ±(1.5%×display value+10uA)
    Leakage current setting alarm rangeMax.: 0.05~20.00mA; Min.: 0.01~5.00mA
    Test time range/resolution1~300s 1s/step
    Grounding resistance
    Grounding current output range/precisionAC 5.0~30.0A ±(1.5%×setting value+0.2A)
    Grounding resistance measurement range/precision10.0~600mΩ ±(1.5%×display value+3mΩ)
    Grounding resistance alarm setting rangeMax.: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;
    Min.: 0.0~100mΩ
    Test time range/resolution1~300s 1s/step
    No-load power
    Output voltage1.0 times rated voltage, built-in variable frequency inverter
    Output voltage measurement range/precisionAC 50~280V ±(0.2%×display value+0.05%×measuring range)
    Output current measurement range/precisionAC 0.20~30.00A ±(0.2%×display value+0.05%×measuring range)
    Active power measurement range/precision30~6000W ±(0.2%×display value+0.05%×measuring range)
    Power setting alarm rangeMax.: 3~6000W ; Min.: 0~6000W
    Test time range/resolution1~300s 1s/step
    Low voltage start-up
    Output voltage0.85 times rated voltage, built-in variable frequency power
    Output voltage measurement range/precisionAC 50~280V ±(0.5%×display value+2 words)
    Start-up current measurement range/precisionAC 0.20~30.00A ±(0.5%×display value+2 words)
    Current setting alarm rangeMax.: 0.20~30.00A ; Min.: 0.00~25.00A
    Test time range1~300s 1s/step
    DC Hi-pot
    Output voltage setting range/precisionDC 200~6000V ±(1.5%×setting value+5 words)
    Breakdown current measurement range/precision0.10~10.00mA ±(1.5%×display value+5 words)
    Breakdown current preset alarmMax.: 0.10~10.00mA; Min.: 0.00~5.00mA
    Test time range/resolution1~300s 1s/step
    AC Hi-pot
    Output voltage setting range/precisionAC 200~5000V ±(1.5%×setting value+5 words) static
    Breakdown current measurement range/precision0.10~99.99mA ±(1.5%×display value+5 words)
    Breakdown current preset alarmMax.: 0.10~99.99mA; Min.: 0.00~5.00mA
    Test time range/resolution1~300s 1s/step
    Arc detection(optional)1~9 level(9 is the most sensitive level)
    Insulation resistance
    Output voltage setting range/precisionDC 200~1000V ±(3%×reading+5 words)
    Insulation resistance measurement range/precision1~2000MΩ ≤100MΩ:±(5%×display value+3 words) >100 MΩ:±(8%×display value+8 words)
    Insulation resistance alarm setting rangeMax.: 0~2000MΩ; Min.: 1~2000MΩ
    Test time range/resolution1~300s 1s/step